Unapproved Draft IEEE Guide for Breaker Failure Protection of Power Circuit Breakers (Superseded by Approved IEEE Draft)
Available Formats:
Availability: Immediate Download
Language: English
License Type: Single User
Updates: Not Included
About This Item
IEEE PC37.119/D5 is an unapproved draft guide focused on breaker failure protection for power circuit breakers, placing it squarely in power and energy applications. It is intended to help address protection scheme design and coordination issues where breaker failure logic is needed to limit the effects of a failed interruption. As a draft technical document, IEEE PC37.119/D5 is relevant to engineers and planners who need careful guidance during review, specification, or early-stage implementation.
What is IEEE PC37.119/D5?
This draft standard provides guidance for breaker failure protection associated with power circuit breakers, a topic that is central to dependable protection system design. IEEE PC37.119/D5 appears to address how breaker failure functions may be applied, coordinated, and evaluated in power system environments. Because it is identified as an unapproved draft, it should be treated as a working technical reference rather than a finalized requirement document. Its value lies in clarifying expected protection practices and technical considerations for this specific application.
Where is IEEE PC37.119/D5 used?
IEEE PC37.119/D5 is most relevant in substations, switchgear installations, and other power network locations where power circuit breakers are used to interrupt fault current. It may be used by protection engineers, utility personnel, consultants, and equipment specifiers involved in relay settings, control schemes, and breaker failure logic. The document is especially useful when coordinating protection functions across feeder, bus, or transmission-related equipment in power and energy systems, where dependable interruption and backup tripping are important.
Why is IEEE PC37.119/D5 important?
Breaker failure protection helps reduce the risk that a failed breaker will leave a fault uncleared, so guidance in IEEE PC37.119/D5 can support safer and more consistent system design. For projects involving specification, testing, or scheme review, the draft helps define technical expectations and reduce ambiguity around protection performance. Using a document like IEEE PC37.119/D5 can also support procurement and engineering consistency by giving teams a common reference for breaker failure application and coordination.
- Breaker failure protection guidance
- Power circuit breaker applications
- Protection scheme coordination
- Substation and switchgear use
- Draft IEEE technical reference
- Publication Date: 2004
- Standard Status: Inactive
- Publisher: IEEE
- Subject: Power, Energy and Industry Applications
- Official IEEE: Doi link
Need This Standard?
Request a personalized quote today to receive the latest edition in PDF or other available formats.
Need This Standard?
Request a personalized quote today to receive the latest edition in PDF or other available formats.
Summarize with AI
Get quick summaries using your favorite AI engine.
Online Standart Disclaimer
OnlineStandart.com is an authorized reseller of international standards through partnerships with authorized distributors. We do not own the copyrights or trademarks of the standards we sell, including but not limited to those of API, ASHRAE, BSI, SAE, ASTM, IEEE, IEC, ASME, ISO, and others.
All product names, logos, and brands are property of their respective owners. All company, product, and service names used on this website are for identification purposes only. Use of these names, trademarks, and brands does not imply endorsement.
The content provided on this website is for informational purposes only and is intended to promote our reselling services. OnlineStandart.com is not affiliated with or endorsed by any of the standard organizations unless explicitly stated.