SAE AIR790D PDF | Request Standard
Latest

SAE AIR790D

Considerations on Ice Formation in Aircraft and Engine Fuel Systems

Standard by SAE International, 2020-09-18

Available Formats:

  • Availability: Immediate Download
  • Language: English
  • License Type: Single User
  • Updates: Not Included
  • Availability: Request Quote
  • Language: English
  • License Type: Enterprise / Multi User
  • Updates: Included

About This Item

Ice formation in aircraft fuel systems results from the presence of dissolved and undissolved water in the fuel. Dissolved water or water in solution with hydrocarbon fuels constitutes a relatively small part of the total water potential in a particular system with the quantity dissolved being primarily dependent on the fuel temperature and the water solubility characteristics of the fuel. One condition of undissolved water is entrained water, such as water particles suspended in the fuel as a result of mechanical agitation of free water or conversion of dissolved water through temperature reduction. This can be considered as analogous to an emulsion state. Another condition of undissolved water is free water which may be introduced as a result of refueling or the settling of entrained water which collects at the bottom of a fuel tank in easily detectable quantities separated by a continuous interface from the fuel above. Water may also be introduced as a result of condensation from air entering a fuel tank through the vent system. Assuming good quality of uplifted fuel, vapor passing through the aircraft vent system is a significant water introduction mechanism. Entrained water will settle out in time under static conditions and may or may not be drained, depending on the rate at which it is converted to free water. In general, it is not likely that all entrained water can ever be separated from fuel under field conditions. The settling rate depends on a series of factors including temperature, quiescence, and droplet size. The droplet size will vary depending upon the mechanics of formation. Usually the particles are so small as to be invisible to the naked eye, but in extreme cases can cause a slight haziness in the fuel. Free water can be drained from a fuel tank if low point drain provisions are adequate and recommended maintenance actions are followed. Water in solution cannot be removed except by dehydration or by converting it, through temperature reduction, to entrained, then to free water. Water strictly in solution is not a serious problem in aviation fuel so long as it remains in solution. Entrained and free water are the most problematic because of the potential of freezing on the surfaces of the fuel system. Further, entrained water will freeze in cold fuel and tend to stay in solution longer since the specific gravity of ice is approximately the same as that of hydrocarbon fuels. The elimination of undissolved water, to the extent it is practical, in fuel storage, handling, and delivery systems, as well as in aircraft fuel systems, can reduce or eliminate the potential for icing problems. Appropriate testing of fuel systems, subsystems, and components under controlled icing conditions can establish confidence in the safe operation of the aircraft fuel system in such icing conditions. The objective of testing is not necessarily to demonstrate that no icing will occur but rather that the effects of the icing will not create a hazardous condition. Considerations for these measures to control potential icing problems are addressed herein. The purpose of this revision is to organize and combine the useful information from AIR790C and ARP1401 into AIR790D and to expand the document with additional information on icing, fuel, and water management and testing. This revision includes observations and considerations regarding testing methods to provide a basis for a standardized test methodology.
SKU: 1b120790ee2a

  • Publication Date: 2020-09-18
  • Standard Status: latest
  • Publisher: SAE International
  • Document Type: Aerospace Standard
  • Subject: Fuel systems modules, Fuel systems, Fuel tanks, Fuel pumps, Fuel control, Fuel lines, Jet fuel, Fuel filters, Aviation fuels
  • Official SAE: Doi link
  • This Version: AIR790D (2020-09-18)
  • Previous Version: AIR790C (2006-08-24)
  • Previous Version: AIR790B (1999-10-01)
  • Previous Version: AIR790A (1992-08-01)
  • Previous Version: AIR790 (1964-04-20)

Please request information about the document. Contact Page

Online Standart App

Need This Standard?

Need This Standard?

Summarize with AI

ChatGPT Perplexity Google AI Claude Grok

Online Standart Disclaimer

OnlineStandart.com is an authorized reseller of international standards, operating through partnerships with authorized distributors. We do not own the copyrights or trademarks of the standards we sell, including but not limited to those of API, ASHRAE, BSI, SAE, ASTM, IEEE, IEC, ASME, ISO, and others.

All product names, logos, and brands are the property of their respective owners and are used for identification purposes only; their use does not imply endorsement. OnlineStandart.com is not affiliated with or endorsed by any standards development organization unless explicitly stated. The content of this document is for informational purposes only and is intended to promote our licensed reselling services.

Online Standart does not host, distribute, or link to free, unlicensed, or uncertified copies of copyrighted standards. Every document we deliver is a licensed copy obtained through authorized channels and supplied with full licensing documentation. The “Free PDF Download” option on our product pages refers to this free informational document — never to a free copy of any standard.