TS 8060 PDF | Request Standard

TS 8060

Reference Coupler for the Calibration of Earphones Used In Audiometry

This standard describes an interim coupler for ioading an earphone with a specified impedance, when calibrating audiometers, in the frequency range of 125 Hz to 8 000 Hz. The sound pressure developed by an earphone is not, in general, the same in the coupler as in a person’s ear. However, the IEC recommendens its use as a simple and ready.

Standard by TSE, 6.03.1990

Available Formats:

  • Availability: Immediate Download
  • Language: English
  • License Type: Single User
  • Updates: Not Included
  • Availability: Request Quote
  • Language: English
  • License Type: Enterprise / Multi User
  • Updates: Included

About This Item

Legal Notices*

TS 8060 addresses the reference coupler used when calibrating earphone elements in audiometry. In practical measurement terms, a coupler provides the defined acoustic loading under which an earphone is evaluated, helping make sound-pressure measurements more consistent and comparable. The standard’s subject is this intermediate device for the 125 Hz to 8 000 Hz frequency range.

An earphone does not, in general, produce the same sound pressure in a coupler as it does in a human ear. For that reason, couplers are used in audiometric calibration as a controlled reference environment that gives the earphone a specified acoustic impedance. The technical value of this arrangement is consistency: it supports more repeatable comparison between instruments and test setups.

Where the coupler fits in the calibration chain

In general technical context, a reference coupler acts as the interface between the earphone and the measurement system. This matters in audiometers because the earphone’s electrical drive is converted into acoustic output under mechanical and acoustic conditions that affect the result. TS 8060 identifies this specific coupler concept and places it within the calibration chain used for audiometric equipment.

This record also corresponds to a withdrawn standard. Even so, the subject remains technically relevant because it explains why earphone calibration in audiometry depends on a dedicated acoustic loading arrangement rather than on direct free-field assumptions.

SKU: cbd6b3fd1cf4

  • Publication Date: 6.03.1990
  • Standard Status: H (İptal Edilmiş Standard/Withdrawn standard)
  • Publisher: TSE
  • Document Language: tr
  • ICS Classification: 01.020 Terminoloji ( Prensipler ve Koordinasyon ); 33.160.50 Aksesuarlar
  • Pages: 8
  • Source Standard: IEC/R 303 (1970)
  • International Equivalents: IEC 303/R (1970)--; IEC/R 303:1970 EQV--

Online Standart App

Need This Standard?

Need This Standard?

Summarize with AI

ChatGPT Perplexity Google AI Claude Grok

Online Standart Disclaimer

OnlineStandart.com is an authorized reseller of international standards, operating through partnerships with authorized distributors. We do not own the copyrights or trademarks of the standards we sell, including but not limited to those of API, ASHRAE, BSI, SAE, ASTM, IEEE, IEC, ASME, ISO, and others.

All product names, logos, and brands are the property of their respective owners and are used for identification purposes only; their use does not imply endorsement. OnlineStandart.com is not affiliated with or endorsed by any standards development organization unless explicitly stated. The content of this document is for informational purposes only and is intended to promote our licensed reselling services.

Online Standart does not host, distribute, or link to free, unlicensed, or uncertified copies of copyrighted standards. Every document we deliver is a licensed copy obtained through authorized channels and supplied with full licensing documentation. The “Free PDF Download” option on our product pages refers to this free informational document — never to a free copy of any standard.